Computer-aided detection (CAD) of solid pulmonary nodules in chest x-ray equivalent ultralow dose chest CT - first in-vivo results at dose levels of 0.13mSv
abstract
|
OBJECTIVES
To determine the value of computer-aided detection (CAD) for solid
pulmonary nodules in ultralow radiation dose single-energy computed
tomography (CT) of the chest using third-generation dual-source CT
at 100kV and fixed tube current at 70 mAs with tin filtration.
METHODS
202 consecutive patients undergoing clinically indicated standard
dose chest CT (1.8±0.7 mSv) were prospectively included and
scanned with an additional ultralow dose CT (0.13±0.01 mSv)
in the same session. Standard of reference (SOR) was established by
consensus reading of standard dose CT by two radiologists. CAD was
performed in standard dose and ultralow dose CT with two different
reconstruction kernels. CAD detection rate of nodules was evaluated
including subgroups of different nodule sizes (<5, 5-7, >7mm).
Sensitivity was further analysed in multivariable mixed effects
logistic regression.
RESULTS
The SOR included 279 solid nodules (mean diameter 4.3±3.4mm,
range 1-24mm). There was no significant difference in per-nodule
sensitivity of CAD in standard dose with 70% compared to 68% in
ultralow dose CT both overall and in different size subgroups (all
p>0.05). CAD led to a significant increase of sensitivity for
both radiologists reading the ultralow dose CT scans (all
p<0.001). In multivariable analysis, the use of CAD (p<0.001),
and nodule size (p<0.0001) were independent predictors for nodule
detection, but not BMI (p=0.933) and the use of contrast agents
(p=0.176).
CONCLUSIONS
Computer-aided detection of solid pulmonary nodules using ultralow
dose CT with chest X-ray equivalent radiation dose has similar
sensitivities to those from standard dose CT. Adding CAD in ultralow
dose CT significantly improves the sensitivity of radiologists.
|
|
|
citation
|
Messerli M, Kluckert J T, Knitel M, Rengier F, Warschkow R, Alkadhi
H, Leschka S, Wildermuth S, Bauer R. Computer-aided detection (CAD)
of solid pulmonary nodules in chest x-ray equivalent ultralow dose
chest CT - first in-vivo results at dose levels of 0.13mSv. Eur J
Radiol 2016; 85:2217-2224.
|
|
|
type
|
journal paper/review (English)
|
date of publishing
|
11-10-2016
|
journal title
|
Eur J Radiol (85/12)
|
ISSN electronic
|
1872-7727
|
pages
|
2217-2224
|
PubMed
|
27842670
|
DOI
|
10.1016/j.ejrad.2016.10.006
|