70 kVp computed tomography pulmonary angiography: potential for reduction of iodine load and radiation dose
Julian L Wichmann, Xiaohan Hu, Josef M Kerl, Boris Schulz, Claudia Frellesen, Boris Bodelle, Moritz Kaup, Jan-Erik Scholtz, Thomas Lehnert, Thomas J Vogl & Ralf Bauer
abstract
|
PURPOSE
The purpose of the study was to evaluate 70 kVp dual-source computed
tomography pulmonary angiography (CTPA) with reduced iodine load in
comparison with single-source 70 and 100 kVp CTPA with standard
iodine load regarding image quality and radiation dose.
MATERIALS AND METHODS
Three groups with 40 consecutive patients each underwent either
standard single-source 100 kVp (120 mAs; group A), single-source 70
kVp (208 mAs; group B), or dual-source 70 kVp CTPA (416 mAs; group
C). A volume of 70 mL of contrast material with 400 mg I/mL (groups
A, B) or 300 mg I/mL (group C) was administered. Chest diameter,
dose-length product, intravascular signal attenuation, image noise,
signal to noise ratio (SNR), and contrast to noise ratio (CNR) were
compared. Two observers rated subjective image quality regarding
intravascular enhancement and image noise using 5-point scales.
RESULTS
Chest diameter and age were similar (P ≥ 0.28) for all groups.
Compared with group A, the average dose-length product was 59% lower
in group B (67.3 ± 11.8 vs. 164.7 ± 50.6 mGy cm,
P<0.001) and similar between groups A and C (167.7 ± 41.2
mGy cm, P = 0.39). Average SNR and CNR were significantly higher for
group C (21.5 ± 4.7 and 19.0 ± 4.5, respectively)
compared with groups A (18.3 ± 3.5 and 15.8 ± 3.4,
respectively) and B (17.3 ± 5.8 and 15.6 ± 5.5,
respectively; all Ps ≤ 0.001). Subjective image quality ratings
regarding enhancement and noise were highest for group C (1.73
± 0.62 and 2.03 ± 0.66, respectively).
CONCLUSIONS
Compared with standard 100 kVp CTPA, single-source 70 kVp CTPA
allows for significant radiation dose savings with comparable SNR
and CNR, whereas dual-source 70 kVp CTPA results in a superior
objective image quality albeit a reduction of iodine concentration.
|
|
|
citation
|
Wichmann J L, Hu X, Kerl J M, Schulz B, Frellesen C, Bodelle B, Kaup
M, Scholtz J E, Lehnert T, Vogl T J, Bauer R. 70 kVp computed
tomography pulmonary angiography: potential for reduction of iodine
load and radiation dose. J Thorac Imaging 2015; 30:69-76.
|
|
|
type
|
journal paper/review (English)
|
date of publishing
|
1-2015
|
journal title
|
J Thorac Imaging (30/1)
|
ISSN electronic
|
1536-0237
|
pages
|
69-76
|
PubMed
|
25423130
|
DOI
|
10.1097/RTI.0000000000000124
|