Publication

Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool

Journal Paper/Review - Mar 1, 2003

Units
PubMed
Doi

Citation
Lutz A, Willmann J, Pfammatter T, Lachat M, Wildermuth S, Marincek B, Weishaupt D. Evaluation of aortoiliac aneurysm before endovascular repair: comparison of contrast-enhanced magnetic resonance angiography with multidetector row computed tomographic angiography with an automated analysis software tool. Journal of vascular surgery : official publication, the Society for Vascular Surgery [and] International Society for Cardiovascular Surgery, North American Chapter 2003; 37:619-27.
Type
Journal Paper/Review (English)
Journal
Journal of vascular surgery : official publication, the Society for Vascular Surgery [and] International Society for Cardiovascular Surgery, North American Chapter 2003; 37
Publication Date
Mar 1, 2003
Issn Print
0741-5214
Pages
619-27
Brief description/objective

PURPOSE: The purpose of this study was to assess accuracy and reliability of a volumetric analysis of abdominal aneurysms on the basis of multidetector row computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) with a commercially available automated vessel analysis software program. MATERIALS AND METHODS: Twenty patients with abdominal aortic aneurysms underwent preoperative CTA and MRA before endovascular repair. Postdeployment CTA was performed in 15 of these 20 patients (75%). All preoperative CTA and MRA and postdeployment CTA data sets were analyzed with an automated software tool. The length of the stent grafts on postdeployment CTA was measured and compared with the true length of the primary component. Two readers independently evaluated 13 vessel parameters on preoperative CTA and MRA, which are considered to be important in planning stent graft deployment. RESULTS: With the automated analysis software tool, all measurements could be performed on either CTA or MRA data sets. There was no statistically significant difference between postdeployment measurements of stent graft length on CTA and the true dimensions of the implanted stent grafts. Interobserver agreement for all of the measurements with either CTA or MRA was good to excellent (interclass coefficient, 0.71 to 0.99) with only minimal mean differences of measured dimensions between both readers (range, -2.0 to +2.3 mm, Bland-Altman). Intermodality agreement between CTA and MRA was good to excellent (interclass coefficient, 0.62 to 0.98) with small mean differences of measured dimensions between both methods (range, -4.1 to +2.1 mm, Bland-Altman). CONCLUSION: Volumetric measurement with an automated analysis software tool allows a fast, precise, and reliable noninvasive preoperative determination of all aortic dimensions on the basis of either CTA or MRA data sets.